Error codes

 

 

 

 

oL1

Problem : Motor overload

Description : Motor overload protection has been triggered

 

oL2

Problem : Unit overload

Description : Unit overload protection has been triggered

 

ov

Problem : Overvolt

Description : Voltage level : approx. 410 VCC for a category unit 230V : approx. 820 VCC for a category unit 460V; approx. 1 050 VCC for a category unit 575V.

 

PUF

Problem : fuse burned

Description : DC bus fuse has been burned. Check for short circuits in the outputs and check the transistors of the main circuit.

 

rr

Problem : recovery transistor failure

Description: failure of the dynamic braking resistor

 

SC

Problem: load short circuit

Description: the unit's output has been short-circuited

 


 